This project is an analysis of the structural calculations for a two-story Accessory Dwelling Unit (ADU) Garage Conversion, ensuring its stability and compliance with design standards. It includes design data such as material properties, seismic and wind considerations, and load calculations. The structural design covers lateral and gravity load resistance, shear wall design. The analysis ensures that the ADU meets safety, durability, and efficiency requirements while optimizing structural performance.
Location city state:
CA 90803
Building type:
Residental
Project Size type:
Square footage
Project Size:
650
Seismic & Wind Considerations:
Risk Category : II
Seismic & Wind Considerations:
Site Class : D
Seismic & Wind Considerations:
Importance Factor : 1
Seismic & Wind Considerations:
Ss : 1.619
Seismic & Wind Considerations:
S1 : 0.568
Seismic & Wind Considerations:
Site Wind Data
Seismic & Wind Considerations:
Basic Wind Speed : mph
Seismic & Wind Considerations:
Risk Category : II
Seismic & Wind Considerations:
Exposure Category : B
Software & Tools Used:
Enercalc, Autocad,Excel,Word