1531 El Pinal

In the project, we implemented a robust foundation system to ensure structural stability and durability. The design included a 25mm thick mild steel (MS) base plate, circular in shape, welded to a 4x4 square post with a 6mm thick fillet weld. The base plate was securely anchored using four 1-inch J-bolts, each embedded 1 foot into 3000 PSI concrete. To enhance the structural integrity, we incorporated 12 numbers of #4 reinforcement bars and #3 links spaced at 6 inches on center, providing additional support and stability. The entire assembly, including the anchor bolts and base plate, was hot-dip galvanized to prevent corrosion and ensure longevity. The foundation plan and section details were meticulously drafted at a scale of 1-1/2"=1'0", ensuring precise execution and alignment with the project specifications.
Location city state:
1531 El Pinal Drive, Stockton, CA 95205
Building type:
Residental
Project Size type:
Square footage
Seismic & Wind Considerations:
Risk Category: II
Seismic & Wind Considerations:
Exposure Category:C
Seismic & Wind Considerations:
Earthquake Data : Risk
Seismic & Wind Considerations:
Category: II
Seismic & Wind Considerations:
Site Class:D-Default
Seismic & Wind Considerations:
Ss= 0.703
Seismic & Wind Considerations:
S1=0.27
Software & Tools Used:
Enercalc, Autocad,Excel,Word
Structural Engineering
Our customers

Case studies

See how our engineering solutions solved real challenges.
Real projects, real results.
Thomas Fragoza Project
See more   
1531 El Pinal
See more   
Richmond ADU
See more   
1511 Laurel Napa
See more   
11230 N Acala Ave
See more   
7915 Wish Ave
See more   
Homewood
See more   
Contact us
Calculator